Abstract

An evaluation of fluid based transient calorimetric method for measurement of ferrite core losses is presented in this paper. The calorimetric type of measurement of the ferrite core losses is considered to be an attractive solution to overcome the limits of the electrical measurements as it is largely independent of the excitation of the magnetics and the operating frequency. First, the performance of the adiabatic calorimeter with variable stirring speed is evaluated. Further on, the influence of specific heat capacity of different ferrite materials on measurement results was investigated by DC current injection method applied on different ferrite core samples. Finally, the proposed method for measuring ferrite loss is tested experimentally. Experimental results were presented in comparison to the results acquired from analytical calculation.
OriginalspracheEnglisch
Titel2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)
Seiten3308-3313
Seitenumfang6
DOIs
PublikationsstatusVeröffentlicht - 25 Mai 2023
Veranstaltung2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia) - Jeju Island, Korea, Republic of
Dauer: 22 Mai 202325 Mai 2023

Konferenz

Konferenz2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)
Zeitraum22/05/2325/05/23

Fingerprint

Untersuchen Sie die Forschungsthemen von „Evaluating Fluid Based Transient Calorimetric Method for Measurement of the Ferrite Core Losses“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren