Evaluating Fluid Based Transient Calorimetric Method for Measurement of the Ferrite Core Losses

Research output: Conference proceeding/Chapter in Book/Report/Conference Paperpeer-review

Abstract

An evaluation of fluid based transient calorimetric method for measurement of ferrite core losses is presented in this paper. The calorimetric type of measurement of the ferrite core losses is considered to be an attractive solution to overcome the limits of the electrical measurements as it is largely independent of the excitation of the magnetics and the operating frequency. First, the performance of the adiabatic calorimeter with variable stirring speed is evaluated. Further on, the influence of specific heat capacity of different ferrite materials on measurement results was investigated by DC current injection method applied on different ferrite core samples. Finally, the proposed method for measuring ferrite loss is tested experimentally. Experimental results were presented in comparison to the results acquired from analytical calculation.
Original languageEnglish
Title of host publication2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)
Pages3308-3313
Number of pages6
DOIs
Publication statusPublished - 25 May 2023
Event2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia) - Jeju Island, Korea, Republic of
Duration: 22 May 202325 May 2023

Conference

Conference2023 11th International Conference on Power Electronics and ECCE Asia (ICPE 2023 - ECCE Asia)
Period22/05/2325/05/23

Keywords

  • Ferrites
  • Temperature measurement
  • Power measurement
  • Fluids
  • Current measurement
  • Measurement uncertainty
  • Core loss