Abstract
The objective of this paper is to present a simple alternative method to determine the transfer impedance of coaxial cables of different lengths and referring them to a per-unit-length parameter. The transfer impedance of any cable is of interest since it accounts for coupling between cables (crosstalk), for pick-up of external signals and also for emission of electromagnetic energy. The method proposed here employs a direct injection of a current into the center conductor and into the braid simultaneously from either end of the cable. The alternative method uses a modified line injection. The modified line injection employs a common mode line injection as well as a differential mode line injection. For both ways of current injection equivalent circuits will be shown and the results will be contrasted. The results are based on a forward gain measurement of distinct lengths of the same quality of coax cables and require little post processing.
Originalsprache | Englisch |
---|---|
Titel | 2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE |
Seiten | 1-5 |
Seitenumfang | 5 |
DOIs | |
Publikationsstatus | Veröffentlicht - 25 Sep. 2020 |
Extern publiziert | Ja |
Veranstaltung | 2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE - Rome, Italy Dauer: 23 Sep. 2020 → 25 Sep. 2020 |
Konferenz
Konferenz | 2020 International Symposium on Electromagnetic Compatibility - EMC EUROPE |
---|---|
Zeitraum | 23/09/20 → 25/09/20 |